Aiwa NSX-AJ20 Manual de Serviço Página 72

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 298
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 71
1-4-23
2AV/X
Description
Maintenance
item No.
1-4
U100 Setting the surface potential
Description
Changes the surface potential by changing the grid control voltage. Also performs main charging.
Purpose
To set the surface potential or check main charging. Also used when reentering data after replacing the
backup RAM or initializing the set data.
Start
Press the start key. The screen for selecting an item is displayed.
Changing the grid control voltage
Turning the main charger on
Turning the main charger on and the laser scanner unit on and off
Display
MC DATA
MC ON
LASER ON/OFF
Description
Method for main charger output
1. Select either MC ON or LASER ON/OFF using the cursor up/down keys.
2. Press the start key. The selected operation starts.
3. To stop operation, press the stop/clear key.
Setting the grid control voltage
1. Select MC DATA using the cursor up/down keys.
2. Change the setting using the cursor left/right keys.
Description
Grid control voltage
Setting range
Initial setting
0 to 255 184
Increasing the setting makes the surface potential higher, and decreasing it makes the potential lower.
Change in value per step: approximately 3.6 V
3. Press the start key. The value is set.
Interrupt copy mode
While this maintenance item is being performed, copying from an original can be made in interrupt copy
mode.
Completion
Press the stop/clear key at the screen for selecting an item when main charger output stops. The screen for
selecting a maintenance item No. is displayed.
Vista de página 71
1 2 ... 67 68 69 70 71 72 73 74 75 76 77 ... 297 298

Comentários a estes Manuais

Sem comentários